EPA 608 Core Practice Test – Free Questions with Answers

Ozone, the Clean Air Act, the 3 Rs, recovery, evacuation, safety and shipping. Every technician must pass Core. Tap an answer to check it.

Score: 0 / 0 (40)
Question 1

Which element in CFC and HCFC refrigerants destroys stratospheric ozone?

Question 2

R-12 is what type of refrigerant?

Question 3

R-22 is what type of refrigerant?

Question 4

R-134a is what type of refrigerant?

Question 5

Put these refrigerant types in order of ozone depletion potential (ODP), highest first.

Question 6

Why do CFCs reach the stratosphere?

Question 7

A loss of stratospheric ozone leads to more of which kind of radiation reaching the earth?

Question 8

Which is a health or environmental effect of ozone depletion?

Question 9

What is the evidence that CFCs and HCFCs cause ozone depletion?

Question 10

HFC refrigerants do not deplete ozone, but what is their environmental concern?

Question 11

What is the Montreal Protocol?

Question 12

When did production of CFCs end in the United States?

Question 13

Since January 1, 2020, what is no longer allowed for R-22?

Question 14

Under the Clean Air Act, intentionally venting CFC or HCFC refrigerant during service is:

Question 15

Does the venting prohibition also apply to substitute refrigerants such as HFCs?

EPA 608 Prep app icon

Get all 381 questions in the app

Mock exams of 25 questions like test day, a readiness score for every section, mistake review and the 100-question Universal exam. English and Español, no ads.

▶ Get it on Google Play
Question 16

Which release of refrigerant is NOT a violation (de minimis)?

Question 17

What is the maximum civil penalty under the Clean Air Act for a refrigerant violation?

Question 18

Who may buy refrigerant in containers for stationary equipment under the sales restriction?

Question 19

Which equipment is covered by the Section 608 rules?

Question 20

Does Section 608 technician certification expire?

Question 21

Recovery and recycling equipment must be:

Question 22

Reclaimed refrigerant must meet which purity standard before it is resold?

Question 23

What is the difference between system-dependent and self-contained recovery equipment?

Question 24

Which refrigerant is used in low-pressure appliances?

Question 25

Under the Section 608 definitions, R-22 and R-410A are used in which kind of appliance?

Question 26

Under the Section 608 definitions, R-134a is used in which kind of appliance?

Question 27

Refrigerant recovered from an appliance and put back into a different owner's equipment must first be:

Question 28

Are there any true 'drop-in' replacements for CFC and HCFC refrigerants?

Question 29

Which lubricant is normally used with HFC refrigerants such as R-134a?

Question 30

Which lubricant is often used with HCFC refrigerants such as R-22?

Question 31

What is fractionation?

Question 32

How should a zeotropic blend (such as R-407C) be charged?

Question 33

In the refrigeration cycle, where does the refrigerant absorb heat?

Question 34

What leaves the compressor discharge?

Question 35

What happens to the refrigerant in the condenser?

Question 36

What does the metering device (expansion valve) do?

Question 37

What color is a standard low-side (compound) gauge?

Question 38

What color is a standard high-side gauge and hose?

Question 39

A compound gauge reads:

Question 40

To 'recover' refrigerant means to:

Want more Core questions?

These are the first 40 of 121 Core questions. The app has all of them, plus timed mock exams that mix questions like the real test.

EPA 608 Prep app icon

Get all 381 questions in the app

Mock exams of 25 questions like test day, a readiness score for every section, mistake review and the 100-question Universal exam. English and Español, no ads.

▶ Get it on Google Play

← All sections

Official sources

The questions are written by us from these U.S. government sources. Always check them for the current rules.